Review of IS 456:2000
there is lots of importing point provide on IS456:2000 code book,which is used in practical civil engineering practices, some of them are listed below
- PH of water shall not be less than 6 (clause 5.4.2)
- Spacers or chairs should be placed at a maximum spacing of 1 m.(clause 12.3.2)
- Maximum permissible free fall of concrete may be taken as 1.5m (clause 13.2)
- The tremie pipe shall be not less than 200mm in diameter
- Structural exceeding 45m in length are designed with one or more expansion joint.(clause 27.2)
- Table 2, shows different grade of concrete
- Modulus of elasticity of steel shall be taken as 200 kn/mm2 (clause 5.6.3)
- Crossing bar should not be tack-welded for assembly of reinforcement unless permitted by engineer in charge.(clause 12.2.1)
- Tolerance for cover. (clause 12.3.2)
- Transportation and handling of concrete.(clause 13.1 & 13.1.1)
- Flexural strength of concrete = 0.75 sqrt Fck (clause 6.2.2)
- Adjustment to minimum cement content for aggregate other than 20mm nominal maximum size.(Table 6)
- Proportion for nominal mix concrete is provided in table 9.
- Minimum number of main steel reinforcement bar provided in reinforced cement concrete are for rectangle column = 4 and for circular column = 6.
- When the bar of two different diameter are to be spliced, the lap length shall be calculated on the basis of diameter of the smaller one.(clause 26.2.5.1)
- The main reinforcement bar in column should not be less than 12mm diameter.(clause 26.5.3.1 d)
- Stripping time of form work is provided in clause 11.3.1.
- Standard deviation is shown in table 8 of IS456:2000.
- Spacers, cover block should be concrete of same strength or Pvc.(clause 12.3.2)
- The detail on compaction is provided on IS2505, IS2506, IS2514, and IS4656.
- Reinforcement shall be bent & fixed in according with procedure specified in IS2502.(clause 12.1)
- The diameter of reinforcing bar shall not exceed 1/8th of total thickness of slab.(clause 26.5.2.2)
- Lap splices shouldn’t be used for bars larger than 36mm,we should prefer welding instead.(clause 26.2.5.1 a)
- Modulus of elasticity of concrete = 5000 sqrt Fck. (clause 6.2.2)
- Minimum cement content, maximum w/c ratio and grade of concrete for different exposure with 20mm nominal maximum size. This is explained in table 5 of IS456:2000.
- Nominal mix concrete may be used for concrete of M20 or lower.(clause 9.3)
- Detailed explanation of placing of concrete is provided in clause 13.2.
- Unit weight of Pcc is 24kn/m3 and Rcc is 25kn/m3.(clause 19.2.1)
- Deflection in flexural member in mm is 40l^2/D.(clause 17.6.3.1)
- Clause 12.3.1 shows the tolerance on placing of reinforcement.
- The structure should be subjected to a load equal to full dead load of the structure plus 1.25 times the imposed load for a period of 24 hours.(clause 17.6.2)
- Clause 17.6.3 shows what if allowable maximum deflection exceeds 40l^2/D.
- IS code for calculation of DL is shown in clause 19.2.1.
- Clause 15.2.2 shows frequency of sampling.
- Minimum curing period of concrete is shown in clause 13.5.1.
- Load considered for structural design. (Clause 19.1).